If the camera called “Mover” does not make a clean lap, please note the following:

  • Make sure you put the scan plate on a flat and even surface. Do not put the scan plate on a carpet!

  • Make sure the scan plate is not standing on a cable etc.

  • Make sure you are using the provided power supply cable "MEANWELL" Output: 18V / 2A / 36W

  • Make sure the power supply cable is firm in the socket and the power LED on the scan plate is shining continuously and stable

  • Do not connect other large power consumers to the same power supply

  • Has anything changed before Mover driving problems occurred?

  • Has the stage been stored and recently reassembled?

  • Was it stored upright?

  • Was the drive belt inside the scan plate ever exchanged? You can see a small part of the drive belt when you take a close look at the park position

    → old belt = all black

    → new belt = white / green

  • Does the Mover have permanent contact with the magnets during the lap and also when back at the park position?

  • Are you using a custom built frame around the scan plate?

  • Make sure the frame does not press on the sides of the scan plate

  • Do not put the scan plate directly on a floor heating system

  • Are you sure the metal top cover plate is firm on the scan plate and it is not loose at any spot?